NSN 5925-00-752-6908 · NIIN 007526908 · FSC 5925
NO DASHES 5925007526908
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.174 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 25.0 AND AMPERES DC 25.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 30.0 AND DC 30.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | QUICK DISCONNECT, FEMALE 2 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.813 |
| CPRQ | RESET METHOD | AUTOMATIC |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 2 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.672 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | WATERTIGHT |
| MATT | MATERIAL | CASE PLASTIC |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-13516 |
| AAQL | BODY STYLE | |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS MAXIMUM 25.0 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION NOMINAL AT 125 PCT 3600.000 AND NOMINAL AT 200 PCT 30.000 |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 |
| AKPX | POLE QUANTITY | 1 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 900.0 AND DC 900.0 |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |