| MRC | Requirement | Value |
|---|---|---|
| AAXH | PRIME MOVER QUANTITY | 1 |
| ACDC | CURRENT TYPE | AC |
| AGBP | MAXIMUM LIFT HEIGHT | FEET 10.0 |
| AJXY | CHAIN TYPE | DIE LOCK LINK |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPS | DUTY CYCLE | INTERMITTENT |
| APHE | OPERATION METHOD | POWERED |
| ASZD | LOAD RATING | POUNDS MAXIMUM 6600.0 |
| ATWP | TRAVEL RATE PER MINUTE | FEET 8.0 |
| ATWR | MECHANICAL ADVANTAGE METHOD | PLANETARY GEAR |
| ATWS | BRAKING METHOD | ELECTRIC |
| ATWT | HOOK QUANTITY | 1 |
| ATWW | LOAD ELEMENT QUANTITY PER HOOK | 1 |
| ATYG | POWER REQUIREMENT RATING | HORSEPOWER 2.00 |
| AWEW | RAISED POSITION DISTANCE BETWEEN SUSPENSION HOOK AND LOAD HOOK BEARING SURFACE | INCHES NOMINAL 24.400 |
| AXGY | MOUNTING METHOD | SUSPENSION HOOK |
| BFMF | COOLING METHOD | SELF-VENTILATED |
| ELEC | VOLTAGE IN VOLTS | 230.0 AND 460.0 |
| FAAZ | PHASE | THREE |
| FEAT | SPECIAL FEATURES | PUSHBUTTON CONTROL; HEAVY DUTY DISC BRAKE; HOIST DUTY MOTOR INCLUDES OVERLOAD PROTECTION THROUGH CONTROLLED TORQUE DESIGN; UPPER AND LOWER OVERTRAVEL LIMIT STOP |
| FREQ | FREQUENCY IN HERTZ | 60.0 |