Home / MS parts / NSN 5925-01-185-0031
NSN 5925-01-185-0031  ·  NIIN 011850031  ·  FSC 5925
NO DASHES 5925011850031
In Stock

CIRCUIT BREAKER

Circuit Breakers

Application: USED IN CONTROL BOX ASSEMBLY NO. 30HK 402024 ON BOARD 270 FT WMEC COASTGUARD VESSELS

Technical characteristics

39 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAQLBODY STYLE
ABTDMOUNTING SLOT WIDTHINCHES NOMINAL 0.164
ADAQBODY LENGTHINCHES MINIMUM 5.768 AND INCHES MAXIMUM 5.832
ADATBODY WIDTHINCHES MINIMUM 3.046 AND INCHES MAXIMUM 3.110
ADAUBODY HEIGHTINCHES MINIMUM 2.577 AND INCHES MAXIMUM 2.641
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 3.515 AND INCHES MAXIMUM 3.579
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.994 AND INCHES MAXIMUM 1.058
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.718 AND INCHES MAXIMUM 2.782
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.994 AND INCHES MAXIMUM 1.058
AFJNFRAGILITY FACTORMODERATELY RUGGED
AGAVEND ITEM IDENTIFICATIONUSED IN CONTROL BOX ASSEMBLY NO. 30HK 402024 ON BOARD 270 FT WMEC COASTGUARD VESSELS
AJECBOSS HEIGHTINCHES MINIMUM 0.187 AND INCHES MAXIMUM 0.251
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 34.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 480.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 40.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.138
CQQCTRIP RELEASE DUTY CYCLEALL LOCATIONS CONTINUOUS
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 40.000 AND MAXIMUM AT 200 PCT 100.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
FREQFREQUENCY IN HERTZ60.0
MATTMATERIALCASE PLASTIC
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYCOMPRESSION 6