Home / MS parts / NSN 5925-00-809-1800
NSN 5925-00-809-1800  ·  NIIN 008091800  ·  FSC 5925
NO DASHES 5925008091800
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

32 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES NOMINAL 0.250
ADAQBODY LENGTHINCHES MAXIMUM 2.189
ADATBODY WIDTHINCHES NOMINAL 0.750
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 3500.0 AND DC 4000.0
THSDTHREAD SERIES DESIGNATORUNS
TTQYTERMINAL TYPE AND QUANTITYTAB W/SCREW 2
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
CPRPULTIMATE TRIP TIME PER POLE IN SECONDSSINGLE LOCATION MAXIMUM 3600.000
CQJXNOMINAL THREAD SIZEINCHES 0.469
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.312
AKPXPOLE QUANTITY1
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH BUTTON 1
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 20.0 AND AMPERES DC 20.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 120.0 AND DC 30.0
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT AND EXPLOSION RESISTANT AND FUNGUS PROOF
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
FREQFREQUENCY IN HERTZ400.0
CPRWACTUATOR FUNCTIONTRIP-RESET
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 25.000 AND MAXIMUM AT 200 PCT 100.000
MATTMATERIALCASE PLASTIC
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CPRQRESET METHODMANUAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.906

Supersedes

This item replaces cancelled NIIN 007693470. An older drawing citing one of those numbers resolves here.