NSN 6625-01-246-5550 · NIIN 012465550 · FSC 6625
NO DASHES 6625012465550
In Stock
TEST SET,TELECOMMUNICATION SYSTE
Electrical and Electronic Properties Measuring and Testing Instruments
Application: AN/FTC-31 COMMUNICATION SYSTEM
Technical characteristics
12 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABGL | WIDTH | INCHES NOMINAL 17.250 |
| ACYN | AC VOLTAGE RATING | LOCATION NOT OTHERWISE SPECIFIED VOLTS MINIMUM 100.0 AND VOLTS MAXIMUM 240.0 |
| ACZB | FREQUENCY RATING | LOCATION NOT OTHERWISE SPECIFIED HERTZ MINIMUM 48.0 AND HERTZ MAXIMUM 66.0 |
| AEJZ | DEPTH | INCHES NOMINAL 13.500 |
| AGAV | END ITEM IDENTIFICATION | AN/FTC-31 COMMUNICATION SYSTEM |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPZ | ENCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
| AQXY | TEST TYPE FOR WHICH DESIGNED | COMMUNICATION ANALYZER PERFORMS MANY DATA CIRCUIT TESTS AND FUNCTIONS INCLUDING ERROR ANALYSIS,MESSAGE GENERATION AND ANALYSIS,DATA TRAPPING,DISTORTION AND DELAY MEASUREMENTS,CLOCK FREQUENCY MEASUREMENTS AND VOICE FREQUENCY MEASUREMENTS |
| FAAZ | PHASE | SINGLE |
| FEAT | SPECIAL FEATURES | OPERATING MODES ARE FULL DUPLEX,HALF DUPLEX CONTINUOUS,HALF DUPLEX SINGLE,SINGLE TRANSMIT,AND SELF TEST MODE;TIMING IS SYNCHRONOUS AND RECOVERED CLOCK FROM 10 B/S TO 500 KB/S;ASYNCHRONOUS FROM 10 B/S TO 20 KB/S;REMOTE AND AUTOMATIC TESTING VIA RS-232,IEEE-488 OR HP-IL CONTROL INTERFACES |
| FTLD | FUNCTIONAL DESCRIPTION | MEASURES THE DELAY TIME BETWEEN ANY TWO SELECTED EVENTS;MEASUREMENTS STARTS THE RISING OR FALLING EDGE OF DTR,DSR,RTS,CTS,CD,GENERATOR DATA,END OF TRANSMISSION OR REAR PANEL INPUT X;ENDS ON DETECTION OF THE RISING OR FALLING EDGE OF DTR,DSR,RTS,CTS,CD,RECEIVE DATA,DETECTION OF TRAP CHARACTERS OR REAR PANEL INPUT Y |
| HGTH | HEIGHT | INCHES NOMINAL 5.250 |