NSN 6130-01-518-5008 · NIIN 015185008 · FSC 6130
NO DASHES 6130015185008
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: CX270T(1GE11),WORKSTATION SMT OPTIPLEX
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | MILLIMETERS NOMINAL 140.0 |
| ABKW | OVERALL HEIGHT | MILLIMETERS NOMINAL 86.0 |
| ABMK | OVERALL WIDTH | MILLIMETERS NOMINAL 150.0 |
| AGAV | END ITEM IDENTIFICATION | CX270T(1GE11),WORKSTATION SMT OPTIPLEX |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| APNX | INPUT VOLTAGE RATING | FIRST OPERATING POWER RQMT AC VOLTS MINIMUM 90.0 AND AC VOLTS MAXIMUM 135.0 |
| APNX | INPUT VOLTAGE RATING | SECOND OPERATING POWER RQMT AC VOLTS MINIMUM 180.0 AND AC VOLTS MAXIMUM 265.0 |
| APPA | OUTPUT VOLTAGE RATING | FIFTH POWER OUTPUT AC VOLTS NOMINAL -12.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT AC VOLTS NOMINAL 12.0 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT AC VOLTS NOMINAL -5.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT AC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT AC VOLTS NOMINAL 3.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| APTQ | INPUT FREQUENCY RATING | SECOND OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS 0.1 TO 25.0 |
| BGQR | OUTPUT WATTAGE RATING | MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS WATTS MAXIMUM 250.0 |
| CWHM | INPUT CURRENT RATING | FIRST OPERATING POWER RQMT AC AMPERES NOMINAL 6.0 |
| CWHM | INPUT CURRENT RATING | SECOND OPERATING POWER RQMT AC AMPERES NOMINAL 3.0 |
| CWKG | VENTILATION DESIGN TYPE | SINGLE FAN |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | (INAVY)PWR SUPPLY,250W PFC |