NSN 5925-00-399-5980 · NIIN 003995980 · FSC 5925
NO DASHES 5925003995980
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 115.0 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 1200.0 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 2 |
| FEAT | SPECIAL FEATURES | LUMINESCENT RED BAND VISIBLEIN TRIP POSITION |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 0.750 |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| AKPX | POLE QUANTITY | 1 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.188 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.688 |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | PUSH-PULL 3 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.138 |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 10.000 AND MAXIMUM AT 200 PCT 100.000 AND NOMINAL AT 400 PCT 10.000 AND NOMINAL AT 138 PCT 3600.000 |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS NOMINAL 25.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 15.0 |
Supersedes
This item replaces cancelled NIIN 005057578. An older drawing citing one of those numbers resolves here.