| MRC | Requirement | Value |
|---|---|---|
| CWGH | OUTPUT CURRENT RATING | SINGLE POWER OUTPUT DC AMPERES NOMINAL 1.25 |
| APPA | OUTPUT VOLTAGE RATING | SINGLE POWER OUTPUT DC VOLTS NOMINAL 12.0 |
| BHQN | RECTIFICATION METHOD | INVERTER AC TO DC |
| CWHM | INPUT CURRENT RATING | SINGLE OPERATING POWER RQMT AC AMPERES NOMINAL 0.3 |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |
| CBBL | FEATURES PROVIDED | OVER VOLTAGE PROTECTOR |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | POWER SUPPLY |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | SINGLE POWER OUTPUT MICROVOLTS PEAK 120.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.30 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.04 |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | METERS 3000.0 |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| CWHJ | OUTPUT CONNECTION TYPE | SINGLE POWER OUTPUT SCREW |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -20.0 TO 70.0 |
| BGQR | OUTPUT WATTAGE RATING | SINGLE POWER OUTPUT WATTS NOMINAL 15.0 |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 85.0 AND AC VOLTS MAXIMUM 264.0 |