Home / MS parts / NSN 5925-01-137-0159
NSN 5925-01-137-0159  ·  NIIN 011370159  ·  FSC 5925
NO DASHES 5925011370159
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

38 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MINIMUM 0.203 AND INCHES MAXIMUM 0.235
ADAQBODY LENGTHINCHES MINIMUM 5.984 AND INCHES MAXIMUM 6.016
ADATBODY WIDTHINCHES MINIMUM 2.984 AND INCHES MAXIMUM 3.010
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 5.109 AND INCHES MAXIMUM 5.141
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 1.484 AND INCHES MAXIMUM 1.516
AEBVUNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.164
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 4.578 AND INCHES MAXIMUM 4.610
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 3.984 AND INCHES MAXIMUM 4.016
AKPXPOLE QUANTITY2
AXHRMOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 2
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 50.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 15000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYALARM 2
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL BETWEEN POLE ONE AND TWO
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS PROOF
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 40.0
CRTKSWITCH TERMINAL TYPEWIRE LEAD
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 15.0 AND DC 0.25
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 240.0 AND DC 250.0
FREQFREQUENCY IN HERTZ60.0
MATTMATERIALCASE PLASTIC
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER TER-INAL AND CONTACT SURFACES
PRMTPRECIOUS MATERIALSILVER
TTQYTERMINAL TYPE AND QUANTITYCOMPRESSION 4