NSN 6130-01-387-1923 · NIIN 013871923 · FSC 6130
NO DASHES 6130013871923
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: REU H; USED ON: AN/MST-T1(V);NEXTHIGHER ASSEMBLY P/N 3003949
Technical characteristics
33 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 8.500 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.630 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 3.130 |
| AGAV | END ITEM IDENTIFICATION | REU H; USED ON: AN/MST-T1(V);NEXTHIGHER ASSEMBLY P/N 3003949 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 103.0 AND AC VOLTS MAXIMUM 127.0 |
| APPA | OUTPUT VOLTAGE RATING | FIFTH POWER OUTPUT DC VOLTS NOMINAL 300.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL -400.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL -400.0 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS NOMINAL 13.4 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL 6.7 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -40.0 TO 85.0 |
| CBBL | FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND OVER CURRENT PROTECTOR |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 0.3 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES NOMINAL 0.3 |
| CWGH | OUTPUT CURRENT RATING | FOURTH POWER OUTPUT DC AMPERES NOMINAL 6.5 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES NOMINAL 6.5 |
| CWGH | OUTPUT CURRENT RATING | FIFTH POWER OUTPUT DC AMPERES NOMINAL 0.3 |
| CWHC | OUTPUT CONTROL LOCATION | THIRD POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | FIRST POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | FOURTH POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | FIFTH POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | SECOND POWER OUTPUT FRONT PANEL |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 |
| CWHJ | OUTPUT CONNECTION TYPE | FIRST POWER OUTPUT THREADED STUD |
| CWHJ | OUTPUT CONNECTION TYPE | SECOND POWER OUTPUT THREADED STUD |
| CWHJ | OUTPUT CONNECTION TYPE | FIFTH POWER OUTPUT THREADED STUD |
| CWHJ | OUTPUT CONNECTION TYPE | FOURTH POWER OUTPUT THREADED STUD |
| CWHJ | OUTPUT CONNECTION TYPE | THIRD POWER OUTPUT THREADED STUD |
| CWHQ | INPUT CONNECTION TYPE | SINGLE OPERATING POWER RQMT THREADED STUD |
| CWHT | INPUT CONNECTION QUANTITY | 1 |
| FEAT | SPECIAL FEATURES | OUTPUT VOLTAGES ARE ISOLATED FROMINPUT AND CASE; COOLING IS THROUGH THEBASEPLATE MOUNTING SURFACE |