NSN 5915-00-243-9281 · NIIN 002439281 · FSC 5915
NO DASHES 5915002439281
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 6.062 |
| ADAQ | BODY LENGTH | INCHES MINIMUM 5.938 AND INCHES MAXIMUM 6.062 |
| ADAT | BODY WIDTH | INCHES NOMINAL 2.500 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 4.250 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 5.000 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 85.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 60.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 25.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 25.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.25 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.25 |
| AHBN | INPUT TERMINAL MANUFACTURER CODE | 96906 |
| AHBP | INPUT TERMINAL IDENTIFICATION | MS3102E18-11P |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED STUD(S) 2 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION THREADED STUD OUTPUT 2 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 125.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 125.0 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.190 |
| STYL | STYLE DESIGNATOR |