NSN 5915-01-137-6440 · NIIN 011376440 · FSC 5915
NO DASHES 5915011376440
In Stock
FILTER,BAND PASS
Filters and Networks
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADAQ | BODY LENGTH | INCHES NOMINAL 6.200 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.250 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.000 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 5.700 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 1.050 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -0.0 TO 60.0 |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED GIGAHERTZ BLANK 2.5 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED BLANK 1.6 |
| AHCH | AVERAGE POWER RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED WATTS BLANK 1.0 |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 4 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 1.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED GIGAHERTZ BLANK 1.35 AND GIGAHERTZ BLANK 1.75 AND GIGAHERTZ BLANK 3.25 AND GIGAHERTZ BLANK 3.70 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.138 |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED GIGAHERTZ BLANK 1.75 AND GIGAHERTZ BLANK 3.25 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM BLANK 60.0 AND MAXIMUM BLANK 3.0 |
| CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED GIGAHERTZ BLANK 1.75 AND GIGAHERTZ BLANK 3.25 |
| STYL | STYLE DESIGNATOR |