NSN 4410-00-089-5739 · NIIN 000895739 · FSC 4410
NO DASHES 4410000895739
In Stock
BOILER,STEAM,HIGH PRESSURE
Industrial Boilers
Technical characteristics
14 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ACDC | CURRENT TYPE | AC |
| ACZB | FREQUENCY RATING | HERTZ NOMINAL 60.0 |
| AMSE | VOLTAGE RATING | VOLTS NOMINAL 440.0 |
| ARNH | OPERATING POSITION | HORIZONTAL |
| ASND | DRAFT TYPE | FORCED |
| ASQR | FIRING TYPE | OIL |
| AWGH | TUBE TYPE | FIRE |
| BKXM | DRUM QUANTITY | 1 |
| BLHL | STEAM CAPACITY | POUNDS PER HOUR NOMINAL 800.000 |
| BLHS | OIL BURNER QUANTITY | 1 |
| BLJC | IGNITION METHOD | ELECTRICAL |
| CQQF | OPERATING PRESSURE | POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM 100.0 |
| FAAZ | PHASE | THREE |
| SHPE | SHAPE | STRAIGHT |