Home / MS parts / NSN 5915-01-076-4534
NSN 5915-01-076-4534  ·  NIIN 010764534  ·  FSC 5915
NO DASHES 5915010764534
In Stock

FILTER,BAND PASS

Filters and Networks

Technical characteristics

28 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABKWOVERALL HEIGHTINCHES NOMINAL 0.630
ADAQBODY LENGTHINCHES NOMINAL 2.700
ADATBODY WIDTHINCHES NOMINAL 1.000
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.690
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.605
AFGAOPERATING TEMP RANGECELSIUS -40.0 TO 85.0
AHAJREFERENCE FREQUENCY PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 9.25
AHAUINPUT IMPEDANCE PER FUNCTION W/LOADLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0
AHAVOUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0
AHBNINPUT TERMINAL MANUFACTURER CODE94990
AHBPINPUT TERMINAL IDENTIFICATIONSMA
AHBSOUTPUT TERMINAL MANUFACTURER CODE94990
AHBTOUTPUT TERMINAL IDENTIFICATIONSMA
AHBZVOLTAGE STANDING WAVE RATIO PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED BLANK 1.4
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 4
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSLOCATION NOT OTHERWISE SPECIFIED BLANK 1.5
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 8.75 AND MEGAHERTZ BLANK 8.90 AND MEGAHERTZ BLANK 9.60 AND MEGAHERTZ BLANK 10.00
CQJXNOMINAL THREAD SIZEINCHES 0.112
CQRGBODY MATERIALMETAL
CRBBFREQUENCY BAND WIDTH PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 8.90 AND MEGAHERTZ BLANK 9.60
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM BLANK 55.0 AND MAXIMUM BLANK 1.00
CRBNVOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 8.9 AND MEGAHERTZ BLANK 9.6
FEATSPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ5.000
STYLSTYLE DESIGNATOR

Supersedes

This item replaces cancelled NIIN 012430623. An older drawing citing one of those numbers resolves here.