MRCRequirementValue
CMLPTHREAD QUANTITY PER INCH32
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1200.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 3
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 30.0
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.812
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 120.0
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.750
AFJNFRAGILITY FACTORMODERATELY RUGGED
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES NOMINAL 0.250
ADAQBODY LENGTHINCHES NOMINAL 2.250
ADATBODY WIDTHINCHES NOMINAL 1.218
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.704
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 25.0
CTJSUNPACKAGED UNIT WEIGHTGRAMS NOMINAL 150.0
FEATSPECIAL FEATURESINCLUDES INSULATING INTERPHASE BARRIERS BETWEEN POLES
FREQFREQUENCY IN HERTZ400.0
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER CONTACTS AND TER-INAL SURFACES
PRMTPRECIOUS MATERIALSILVER
PRPYPROPRIETARY CHARACTERISTICSPACS
THSDTHREAD SERIES DESIGNATORUNS
TTQYTERMINAL TYPE AND QUANTITYTAB W/SCREW 6
ZZZKSPECIFICATION/STANDARD DATAPROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION 29957-5114-1801
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.419
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 15.000 AND MAXIMUM AT 200 PCT 55.000