NSN 6130-01-356-3740 · NIIN 013563740 · FSC 6130
NO DASHES 6130013563740
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: ALQ184
Technical characteristics
39 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 16.600 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 7.000 |
| ADZC | ENVIRONMENTAL PROTECTION | SALT SPRAY PROOF |
| AGAV | END ITEM IDENTIFICATION | ALQ184 |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 50000.0 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT THREE |
| APNX | INPUT VOLTAGE RATING | FOURTH OPERATING POWER RQMT DC VOLTS NOMINAL 15.0 |
| APNX | INPUT VOLTAGE RATING | SIXTH OPERATING POWER RQMT DC VOLTS NOMINAL -15.0 |
| APNX | INPUT VOLTAGE RATING | SECOND OPERATING POWER RQMT DC VOLTS NOMINAL 64.0 |
| APNX | INPUT VOLTAGE RATING | THIRD OPERATING POWER RQMT DC VOLTS NOMINAL 28.0 |
| APNX | INPUT VOLTAGE RATING | FIFTH OPERATING POWER RQMT DC VOLTS NOMINAL 5.0 |
| APNX | INPUT VOLTAGE RATING | FIRST OPERATING POWER RQMT AC VOLTS MINIMUM 115.0 AND AC VOLTS MAXIMUM 200.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS MINIMUM 6.3 AND DC VOLTS MAXIMUM 6.6 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC KILOVOLTS MINIMUM -3.9 AND DC KILOVOLTS MAXIMUM -3.896 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC KILOVOLTS MINIMUM 1.69 AND DC KILOVOLTS MAXIMUM 1.945 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ NOMINAL 400.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -54.0 TO 71.0 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC MILLIAMPERES MINIMUM 2.0 AND DC MILLIAMPERES MAXIMUM 3.0 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC MILLIAMPERES MINIMUM 109.0 AND DC MILLIAMPERES MAXIMUM 108.0 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 1.1 |
| CWGN | OUTPUT PHASE | SINGLE POWER OUTPUT THREE |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | THIRD POWER OUTPUT VOLTS RMS 10.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | SECOND POWER OUTPUT VOLTS RMS 0.2 |
| CWHF | OUTPUT CONNECTION QUANTITY | 8 |
| CWHJ | OUTPUT CONNECTION TYPE | SINGLE POWER OUTPUT CONNECTOR, PLUG |
| CWHM | INPUT CURRENT RATING | FOURTH OPERATING POWER RQMT DC AMPERES NOMINAL 0.25 |
| CWHM | INPUT CURRENT RATING | SIXTH OPERATING POWER RQMT DC AMPERES NOMINAL 0.1 |
| CWHM | INPUT CURRENT RATING | SECOND OPERATING POWER RQMT DC AMPERES NOMINAL 1.2 |
| CWHM | INPUT CURRENT RATING | THIRD OPERATING POWER RQMT DC AMPERES NOMINAL 1.5 |
| CWHM | INPUT CURRENT RATING | FIFTH OPERATING POWER RQMT DC AMPERES NOMINAL 5.0 |
| CWHM | INPUT CURRENT RATING | FIRST OPERATING POWER RQMT AC AMPERES MINIMUM 15.0 AND AC AMPERES MAXIMUM 22.0 |
| CWHQ | INPUT CONNECTION TYPE | FIRST ALTERNATE OPERATING POWER RQMT CONNECTOR, RECEPTACLE |
| CWHQ | INPUT CONNECTION TYPE | THIRD ALTERNATE OPERATING POWER RQMT CONNECTOR, RECEPTACLE |
| CWHQ | INPUT CONNECTION TYPE | SECOND ALTERNATE OPERATING POWER RQMT CONNECTOR, RECEPTACLE |
| CWHT | INPUT CONNECTION QUANTITY | 3 |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |
| FEAT | SPECIAL FEATURES | OUTPUT VOLTAGES AND CURRENT RATINGS ARE REQUIRED TO OPERATE ONE TWT. THIS POWER SUPPLY OPERATES 8 DIFF. TWT'S. OVERCURRENT PROTECTION,RELAY RESET WHEN POWER IS CYCLED ON AND OFF |
| ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | SOURCE CONTROLED |