| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MINIMUM 6.875 AND INCHES MAXIMUM 7.125 |
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 6.625 AND INCHES MAXIMUM 6.875 |
| ABMK | OVERALL WIDTH | INCHES MINIMUM 6.437 AND INCHES MAXIMUM 6.687 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETICALLY SEALED |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 10000.0 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 105.0 AND AC VOLTS MAXIMUM 125.0 |
| APPA | OUTPUT VOLTAGE RATING | SINGLE POWER OUTPUT DC VOLTS MINIMUM 18.5 AND DC VOLTS MAXIMUM 20.2 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 420.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -55.0 TO 95.0 |
| BGHX | OUTPUT CONTROL QUANTITY | 1 |
| BGHY | OUTPUT CONTROL TYPE | SINGLE POWER OUTPUT VOLTAGE ADJUSTMENT |
| BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
| CBBL | FEATURES PROVIDED | FILTER |
| CWGH | OUTPUT CURRENT RATING | SINGLE POWER OUTPUT DC AMPERES NOMINAL 6.0 |
| CWHC | OUTPUT CONTROL LOCATION | SINGLE POWER OUTPUT TOP PANEL |
| CWHF | OUTPUT CONNECTION QUANTITY | 2 |
| CWHJ | OUTPUT CONNECTION TYPE | SINGLE POWER OUTPUT FERRULE |
| CWHQ | INPUT CONNECTION TYPE | SINGLE OPERATING POWER RQMT FERRULE |
| CWHT | INPUT CONNECTION QUANTITY | 2 |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |