NSN 5945-00-158-7462 · NIIN 001587462 · FSC 5945
NO DASHES 5945001587462
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJD | THREAD CLASS | 2A |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.218 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 1.187 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 1.187 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.531 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.531 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 150.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY THREADED STUD(S) 4 |
| CBBL | FEATURES PROVIDED | POLARIZED |
| CQJX | NOMINAL THREAD SIZE | SINGLE MOUNTING FACILITY INCHES 0.138 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY RECTANGULAR |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 4 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 14.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 5.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 110.0 AND DC 26.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 14 |