NSN 6020-01-121-6917 · NIIN 011216917 · FSC 6020
NO DASHES 6020011216917
In Stock
CABLE ASSEMBLY,FIBER OPTIC
Fiber Optic Cable Assemblies and Harnesses
Application: AN/ALQ-99 COUNTERMEASURES SET
Technical characteristics
8 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABJH | TEMP RATING | CELSIUS -54.0 AND CELSIUS 110.0 |
| AGAV | END ITEM IDENTIFICATION | AN/ALQ-99 COUNTERMEASURES SET |
| FEAT | SPECIAL FEATURES | CAPABLE OF TRANSMITTING LIGHT W/60 PCT EFFICIENCY; LIGHT ACCEPTANCE ANGLE GREATER THAN 50 DEG |
| MATT | MATERIAL | CORE CONDUCTOR ALL CONDUCTORS STEEL CORROSION RESISTING |
| PMLC | PRECIOUS MATERIAL AND LOCATION | GOLD CONNECTOR AND SILVER CONNECTOR |
| PRMT | PRECIOUS MATERIAL | GOLD AND SILVER |
| SPCL | SPECIAL TEST FEATURES | CORROSION RESISTANT STEEL TUBING SHALL BE PASSIVATED I/A/W QQ-P-35 OR TIN PLATED OR NICKEL AND COPPER; THE BRASS TUBING, IF USED, SHALL BE TIN OR SILVER PLATED; CONNECTOR SHALL BE FABRICATED FROM CORROSION RESISTANT STEEL I/A/W QQ-S-764, CLASS 303 CONDITION A; CONNECTOR SHALL BE GOLD PLATED I/A/W MIL-G-45204, TYPE I, CLASS 2; THE COUPLING NUT MAY BE EITHER GOLD PLATED OR PASSIVATED; |
| TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | OPTICAL ASSEMBLY SHALL BE CAPABLE OF TRANSMITTING LIGHT WITH TRANSMISSION EFFICIANCY OF 50% MINIMUM; THE LIGHT ACCEPTANCE ANGLE SHALL BE GREATER THAN 50V (FULL ANGLE) WHEN OPERATED IN AIR |