NSN 5915-00-880-0689 · NIIN 008800689 · FSC 5915
NO DASHES 5915008800689
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNEF |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 5.920 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.500 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.750 |
| CQRG | BODY MATERIAL | METAL |
| STYL | STYLE DESIGNATOR | |
| AHCG | MAXIMUM TEMP RISE | CELSIUS 25.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| ADAR | BODY OUTSIDE DIAMETER | INCHES NOMINAL 1.750 |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED BUSHING 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION TAB, SOLDER LUG INPUT 1 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | LOCATION NOT OTHERWISE SPECIFIED BLANK 400.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | LOCATION NOT OTHERWISE SPECIFIED BLANK 15.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED VOLTS AC BLANK 1.5 AND VOLTS DC BLANK 1.5 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED INDUCTANCE-CAPACITANCE BLANK |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION TAB, SOLDER LUG OUTPUT 1 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED VOLTS AC BLANK 120.0 AND VOLTS DC BLANK 400.0 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 85.0 |
Supersedes
This item replaces cancelled NIIN 000768601. An older drawing citing one of those numbers resolves here.