NSN 5945-01-129-3394 · NIIN 011293394 · FSC 5945
NO DASHES 5945011293394
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 0.370 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 0.275 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 0.370 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING KILOHMS NOMINAL 1.56 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY TERMINAL 1 |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 26.5 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES DC 1.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD MILLIAMPERES DC 100.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | DC 28.0 |
| FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS WIRE LEAD 8 |
Supersedes
This item replaces cancelled NIINs 013535362 · 013787323 · 010748598 · 011244214 · 011691564. An older drawing citing one of those numbers resolves here.