NSN 5950-01-115-2012 · NIIN 011152012 · FSC 5950
NO DASHES 5950011152012
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 1.930 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 1.560 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 1.600 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.122 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.250 |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 2 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES DC MAXIMUM 3.3 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 0.2 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 11.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 7.20 AND AC VOLTS NOMINAL 6.50 AND AC VOLTS NOMINAL 5.75 AND AC VOLTS NOMINAL 5.00 AND AC VOLTS NOMINAL 4.30 AND AC VOLTS NOMINAL 3.60 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 11 |