NSN 6060-01-483-3283 · NIIN 014833283 · FSC 6060
NO DASHES 6060014833283
In Stock
COUPLER,FIBER OPTIC
Fiber Optic Interconnectors
Application: C130J AIRCRAFT
Technical characteristics
6 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AGAV | END ITEM IDENTIFICATION | C130J AIRCRAFT |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | MIL-STD-1553B MULTIPLEX DATA BUS SPLICED-IN COUPLERS AND TERMINATORS |
| FEAT | SPECIAL FEATURES | THERMAL CYCLING TESTS TO -65 DEGREES CELSIUS TO MAX RATED TEMPERATURE; ALTITUDE IMMERSION: 75,000 FEET; MOISTURE RESISTANCE: 10 DAY CYCLIC HUMIDITY; SALT SPRAY: 1000 HOURS WITHOUT EVIDENCE OF FUNCTIONAL DAMAGE |
| SPCL | SPECIAL TEST FEATURES | SINUSOIDAL VIBRATION TEST: 0.06 IN DOUBLE AMPLITUDE; RANDOM VARIATION: 34RMS; MECHANICAL SHOCK: 100G 6MSEC; FLUIDS RESISTANCE: 39 DEGREES CELSIUS AND 135 DEGREES CELSIUS WITHOUT FUNCTIONAL DAMAGE;WHENEVER IMMERSION IN WATER SOLUTION IS SPECIFIED, THE SOLUTION SHALL CONTAIN SUFFICIENT SODIUM CHLORIDE TO MAKE THE SOLUTION CONDUCTIVE, UNLESS OTHERWISE SPECIFIED IN THE TEST PROCEDURE |
| SUPP | SUPPLEMENTARY FEATURES | FUNCTIONAL TESTING SHALL CONSIST OF TRANSMITTING MIL-STD-1553B WORDS BETWEEN ONE STUB AND ANOTHER OF A SINGLE COUPLER OR A GROUP OF COUPLERS I/A/W 4.5.3.3; NO DETECTED ERRORS SHALL BE ALLOWED; THIS FUNCTIONAL TESTING MAY BE USED INSTEAD OF DISCONTINUITY MONITORING DURING ENVIRONMENTAL TESTING |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT STANDARD -IL-STD-1553B |
Supersedes
This item replaces cancelled NIIN 014756389. An older drawing citing one of those numbers resolves here.