NSN 5996-01-391-8050 · NIIN 013918050 · FSC 5996
NO DASHES 5996013918050
In Stock
AMPLIFIER,RADIO FREQUENCY
Amplifiers
Technical characteristics
8 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AFGA | OPERATING TEMP RANGE | CELSIUS -54.0 TO 95.0 |
| AFHH | AVERAGE LIFE RATING | 5.0 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| BHTH | ATTENUATION IN DECIBELS | 10.0 AND 16.0 |
| BJBM | MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | 20000.0 |
| FEAT | SPECIAL FEATURES | FREQUENCY RANGE: RF PORT: (FL -0.25) GHZ TO (FL+15) GHZ; LO PORT: (FL+0.5) GHZ TO (FL+3.5)GHZ; IF PORT: (FL-1.3)GHZ TO (FL-0.5)GHZ; FOR FREQUENCIES ABOVE (FL+425)GHZ THE MIXER SHALL BE USED IN A 3RD HARMONIC MIXING MODE |
| SPCL | SPECIAL TEST FEATURES | OPERATING TEMPERATURE: BETWEEN SEA LEVEL AND 80,000 FEET; OPERATION ABOVE +85C SHALL BE LIMITED TO 30 MINUTES AT ANY ONE TIME AND OPERATION ABOVE 60,000 FEET WILL BE LIMITED TO 2 MINUTES |
| SUPP | SUPPLEMENTARY FEATURES | FAILURE RATE SHALL BE 3 PER 1 MILLION HOURS; SALT SPRAY: UNITS SHALL BE TESTED I/A/W MIL-STD-202, METHOD 101, TEST CONDITION A; UNITS SHALL BE EXAMINED FOR CORROSION, DETERIORATION, AND LEGIBILITY OF MARKINGS; MANUFACTURER SHALL CERTIFY THAT MATERIALS USED ARE IN COMPLIANCE WITH THE FUNGUS REQUIREMENTS OF MIL-E-5400; ALL VIBRATION TESTS SHALL BE CONDUCTED IN EACH OF THE 3 MUTUALLY PERPENDICULAR PLANES; PERFORMANCE RANDOM VIBRATION: 50 TO 1000HZ: 0.35G (RAISED TO THE 2ND POWER)/HZ; 1000 TO 2000HZ: 6 DB/OCTAVE ROLL OFF; OVERALL: 23G RMS MINIMUM; TEST TIME: 4 HOUR MINIMUM |