NSN 5930-00-009-1326 · NIIN 000091326 · FSC 5930
NO DASHES 5930000091326
In Stock
SWITCH,THERMOSTATIC
Switches
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 1.217 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 0.622 |
| ABPM | BODY DIAMETER | INCHES MAXIMUM 0.572 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 0.364 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | INCHES MINIMUM 0.930 AND INCHES MAXIMUM 0.944 |
| AKBY | TEMP SENSING ELEMENT TYPE | DISC |
| AXGY | MOUNTING METHOD | BRACKET(S) |
| CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION 1 |
| CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES RESISTIVE LOAD 2.0 |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES RESISTIVE LOAD 4.0 |
| CTHF | CONTACT LOAD CURRENT RATING | THIRD VOLTAGE AMPERES RESISTIVE LOAD 6.0 |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | ACTUATION POINT NOMINAL DEGREES FAHRENHEIT 287.00 AND DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT 251.00 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 250.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE AC AT SEA LEVEL 125.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | THIRD VOLTAGE DC AT SEA LEVEL 30.0 |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS |
| STYL | STYLE DESIGNATOR | |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 96906--IL-STD-202 |