Home / MS parts / NSN 5925-00-854-7356
NSN 5925-00-854-7356  ·  NIIN 008547356  ·  FSC 5925
NO DASHES 5925008547356
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

29 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAQLBODY STYLE
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC
ABXDBUSHING LENGTHINCHES MAXIMUM 0.380
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.700
AKPXPOLE QUANTITY1
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 1.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 50.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 500.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.375
ADAQBODY LENGTHINCHES MAXIMUM 1.562
ADATBODY WIDTHINCHES MAXIMUM 0.625
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MAXIMUM 0.906
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 2
CMLPTHREAD QUANTITY PER INCH32
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.055 AND MAXIMUM AT 200 PCT 0.950 AND MAXIMUM AT 400 PCT 0.240
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND HERMETICALLY SEALED
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39019
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRPULTIMATE TRIP TIME PER POLE IN SECONDSSINGLE LOCATION MINIMUM 0.200 AND MAXIMUM 7.000
CPRQRESET METHODMANUAL
THSDTHREAD SERIES DESIGNATORUNEF