Home / MS parts / NSN 5925-00-936-3933
NSN 5925-00-936-3933  ·  NIIN 009363933  ·  FSC 5925
NO DASHES 5925009363933
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

28 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.750
AJECBOSS HEIGHTINCHES NOMINAL 0.250
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITYTERMINAL 6
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS MAXIMUM 40.0
MATTMATERIALCASE PLASTIC
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 25.000 AND MAXIMUM AT 200 PCT 80.000
CPRWACTUATOR FUNCTIONTRIP-RESET
FREQFREQUENCY IN HERTZ60.0
AAQLBODY STYLE
ADAQBODY LENGTHINCHES NOMINAL 3.000
ADATBODY WIDTHINCHES NOMINAL 2.234
ADAUBODY HEIGHTINCHES NOMINAL 2.312
TTQYTERMINAL TYPE AND QUANTITYCLIP 3 AND COMPRESSION 3
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 60.0
CPRQRESET METHODMANUAL
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 5000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
FEATSPECIAL FEATURESUSE MOUNTING KIT SK5668 WHEN REPLACING A Q1B360 BREAKER.

Supersedes

This item replaces cancelled NIIN 012311765. An older drawing citing one of those numbers resolves here.