Home / MS parts / NSN 5925-01-558-6304
NSN 5925-01-558-6304  ·  NIIN 015586304  ·  FSC 5925
NO DASHES 5925015586304
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

37 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS FAHRENHEIT NOMINAL 71.0
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-5809
FEATSPECIAL FEATURESEXTRA LONG PUSH BUTTON
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 20.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSHOCKPROOF AND VIBRATIONPROOF
CQJXNOMINAL THREAD SIZEINCHES 0.438
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MINIMUM 0.219 AND INCHES MAXIMUM 0.281
ADAQBODY LENGTHINCHES MAXIMUM 0.781
ADATBODY WIDTHINCHES MAXIMUM 1.840
ADAUBODY HEIGHTINCHES MAXIMUM 1.381
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S14154
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 20.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 200.0
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT120.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 2000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.469 AND INCHES MAXIMUM 0.531
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.593 AND INCHES MAXIMUM 0.655
AFJNFRAGILITY FACTORMODERATELY RUGGED
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
THSDTHREAD SERIES DESIGNATORUN
TTQYTERMINAL TYPE AND QUANTITYTAB W/SCREW 6
CPRQRESET METHODMANUAL