Home / MS parts / NSN 5925-01-597-1967
NSN 5925-01-597-1967  ·  NIIN 015971967  ·  FSC 5925
NO DASHES 5925015971967
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

19 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAQLBODY STYLE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 30.0 AND AMPERES DC 30.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 115.0 AND DC 28.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRQRESET METHODMANUAL
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
ABHPOVERALL LENGTHINCHES NOMINAL 2.189
ADATBODY WIDTHINCHES MAXIMUM 0.750
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.188
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.812
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.000
AKPXPOLE QUANTITY1
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS MINIMUM -40.0 AND CELSIUS MAXIMUM 71.0
TTQYTERMINAL TYPE AND QUANTITYSCREW 2