NSN 5945-00-815-3494 · NIIN 008153494 · FSC 5945
NO DASHES 5945008153494
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
31 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 2.249 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 1.531 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 4.0 AND AMPERES DC 4.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 6.0 AND AMPERES DC 6.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD AMPERES AC 2.0 AND AMPERES DC 2.0 |
| AAJD | THREAD CLASS | 2A |
| AAJF | THREAD DIRECTION | SINGLE MOUNTING FACILITY RIGHT-HAND |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 1.531 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 1.187 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 1.187 |
| CRXH | TIME DELAY | FIXED OPERATE AND RELEASE TIME SECONDS MAXIMUM 0.02 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 28.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS WIRE HOOK 14 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT STANDARD 96906--S25271 |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 4 |
| CQJX | NOMINAL THREAD SIZE | SINGLE MOUNTING FACILITY INCHES 0.138 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY RECTANGULAR |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY THREADED STUD(S) 4 |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
Supersedes
This item replaces cancelled NIINs 000540257 · 001734375 · 005564407 · 006858743 · 007545336 · 007260074 · 007881165 · 007711567 · 008232125 · 008406674. An older drawing citing one of those numbers resolves here.