Home / MS parts / NSN 5925-00-957-9894
NSN 5925-00-957-9894  ·  NIIN 009579894  ·  FSC 5925
NO DASHES 5925009579894
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

33 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CQJXNOMINAL THREAD SIZEINCHES 0.138
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-13516
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--13516 TO 6BI
CMLPTHREAD QUANTITY PER INCH32
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 8.000 AND MAXIMUM AT 200 PCT 50.000
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
AAQLBODY STYLE
ABHPOVERALL LENGTHINCHES NOMINAL 2.190
ADATBODY WIDTHINCHES NOMINAL 0.750
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.780
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.812
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.430
AKPXPOLE QUANTITY1
TTQYTERMINAL TYPE AND QUANTITYTAB W/SCREW 2
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDVIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
CPRWACTUATOR FUNCTIONTRIP-RESET
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 10.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 28.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 575.0
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH BUTTON 1
MATTMATERIALCASE PLASTIC