NSN 5930-00-841-3398 · NIIN 008413398 · FSC 5930
NO DASHES 5930008413398
In Stock
SWITCH,PRESSURE
Switches
Technical characteristics
25 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJD | THREAD CLASS | 3A |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 1 |
| CTZL | PRESSURE CONNECTOR TYPE | SINGLE CONNECTION INVERTED FLARE, THREADED EXTERNAL |
| MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
| STYL | STYLE DESIGNATOR | |
| CTYM | CONTACT ADJUSTMENT RANGE | ACTUATION POINT POUNDS PER SQUARE INCH 25.00 TO 40.00 AND DEACTUATION POINT POUNDS PER SQUARE INCH GAGE 25.00 TO 40.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE PRESSURE CONNECTION UNF |
| CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| CQJB | PROOF PRESSURE | POUNDS PER SQUARE INCH GAGE 200.00 |
| CQJX | NOMINAL THREAD SIZE | SINGLE PRESSURE CONNECTION INCHES 0.438 |
| CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW |
| CTYX | CONTACT STIMULUS RATING | ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE 32.00 AND DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE 28.00 AND DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH GAGE 4.00 |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 3.410 |
| ABKV | OUTSIDE DIAMETER | SINGLE CONNECTION INCHES NOMINAL 0.438 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.890 |
| ADAV | OVERALL DIAMETER | INCHES NOMINAL 1.820 |
| AJZC | PRESSURE SWITCH TYPE | GAGE |
| AWTN | OPERATING TEMP RATING | FAHRENHEIT MINIMUM -65.0 AND FAHRENHEIT MAXIMUM 275.0 |
| AXGY | MOUNTING METHOD | INLET CONNECTION |
| CBBL | FEATURES PROVIDED | TAMPER PROOF CAP |
| CMLP | THREAD QUANTITY PER INCH | 20 |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CTHF | CONTACT LOAD CURRENT RATING | SINGLE VOLTAGE AMPERES RESISTIVE LOAD 4.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SINGLE VOLTAGE DC AT SEA LEVEL 30.0 |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |