NSN 4140-00-541-4186 · NIIN 005414186 · FSC 4140
NO DASHES 4140005414186
In Stock
FAN,CIRCULATING
Fans, Air Circulators, and Blower Equipment
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADZC | ENVIRONMENTAL PROTECTION | HUMIDITY PROOF AND SHOCK PROOF AND VIBRATION PROOF |
| AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 1650.0 |
| AGBD | ELECTRICAL CONNECTION TYPE | WIRE LEAD |
| AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | INCHES OF WATER (INH20) 0.0 |
| AKCV | DRIVE TYPE | DIRECT |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| SFTT | SURFACE TREATMENT | HOUSING ENAMEL |
| STYL | STYLE DESIGNATOR | |
| FAAZ | PHASE | SINGLE |
| FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| MATT | MATERIAL | OVERALL ALUMINUM ALLOY |
| ADNK | FLOW DIRECTION | INWARD |
| CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ABRY | LENGTH | INCHES NOMINAL 6.250 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | FLANGE 1 AND UNTHREADED HOLE(S) 8 |
| CQKX | AIR FLOW RATE | CUBIC FEET PER MINUTE NOMINAL 500.0 |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | AC 115.0 |
| CSYL | PRIME MOVER POWER RATING | HORSEPOWER 0.013 |
Supersedes
This item replaces cancelled NIIN 004060045. An older drawing citing one of those numbers resolves here.