NSN 4520-00-490-1373 · NIIN 004901373 · FSC 4520
NO DASHES 4520004901373
In Stock
HEATER,WATER,LIQUID FUEL
Space and Water Heating Equipment
Technical characteristics
1 row
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | HIGH PRESSURE,ATOMIZING BURNER; DESIGNED FOR FUEL OIL,GRADE NO. 2,PER FED SPEC VV-F-815; HEATING CAPACITY DATA,560 GAL WATER HEATED PER HR,100 DEG F TEMP RISE PER HR; STORAGE TANK DATA,DESIGNED FOR VERTICAL POS,90 GAL CAPACITY,STEEL,PROTECTIVE FINISH DATA,ZINC-COATED EXTERIOR FINISH,ZINC-COATED INTERIOR FINISH; AUTOMATICALLY CONTROLLED; 125 PSI,MAX WP; WATER CONNECTIONS DATA,INLET,1,2 IN.-11-1/2 NPT,OUTLET,1,2 IN.-11-1/2 NPT; DESIGNED FOR 10.0 IN. FLUE PIPE; INSULATED; OVER-ALL DIM.,66.0 IN. MAX H,33.0 IN. MAX DIA; ELECTRICAL DATA,AC,115 V,60 CYCLES,SINGLE PHASE,NOT RATED FOR WATTAGE; ADDITIONAL EQUIPMENT,CAP,DOWNDRAFT,FLUE PIPE 1,COLLAR,STORM,FLUE PIPE 1,ELBOW,90 DEG FLUE PIPE 2,ELECTRODE LEADS SET,IGNITION 1,PIPE,FLUE,2 FT. LG SECTION 7,REGULATOR,DRAFT 1,ROD SET,ANODE 1,VALVE,RELIEF,COMBINATION PRESSURE AND TEMPERATURE 1; SPECIAL FEATURES,APPROVED FOR INSTALLATION ON COMBUSTIBLE FLOORS,ELECTROMAGNETIC INTERFERNCE CONTROL REQUIRED,FUNGUS RESISTANCE REQUIRED,4.3 GPH FIRING RA |
Supersedes
This item replaces cancelled NIIN 002563215. An older drawing citing one of those numbers resolves here.