Home / MS parts / Electrical & Electronic Components / NSN 5950-00-655-0960
NSN 5950-00-655-0960  ·  NIIN 006550960  ·  FSC 5950
NO DASHES 5950006550960
In Stock

REACTOR

Coils and Transformers

Technical characteristics

23 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT FIRST WINDING MILLIAMPERES DC MAXIMUM 65.0
AKDXWINDING QUANTITY2
CQJXNOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
BKPLRATING METHODSINGLE COMPONENT ALL WINDING ELECTRICAL
CMLPTHREAD QUANTITY PER INCH32
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AKPVMOUNTING FACILITY QUANTITY4
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.875
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.625
ACYFINDUCTANCE TYPEFIXED
ADAUBODY HEIGHTINCHES NOMINAL 4.250
AARGRELIABILITY INDICATORNOT ESTABLISHED
PRPYPROPRIETARY CHARACTERISTICSPACS
THSDTHREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYSOLDER STUD 5
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT SECOND WINDING MILLIAMPERES DC MAXIMUM 30.0
CRGSDC RESISTANCE RATING IN OHMS200.000
CRGSDC RESISTANCE RATING IN OHMS450.000
ADAQBODY LENGTHINCHES NOMINAL 2.625
ADATBODY WIDTHINCHES NOMINAL 2.375
ACYVINDUCTANCE RATINGSINGLE COMPONENT SECOND WINDING HENRY MAXIMUM 20.00
AXGYMOUNTING METHODSINGLE GROUP THREADED STUD(S)
ACYVINDUCTANCE RATINGSINGLE COMPONENT FIRST WINDING HENRY MAXIMUM 8.00