NSN 5950-01-035-2257 · NIIN 010352257 · FSC 5950
NO DASHES 5950010352257
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.800 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.250 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 2.100 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ NOMINAL 9.5 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 135.0 |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 1 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 2 |
| CBBL | FEATURES PROVIDED | W/RECTIFIER |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.250 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY MILLIAMPERES DC MAXIMUM 200.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY DC KILOVOLTS NOMINAL 12.50 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY DC VOLTS NOMINAL 18.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY DC VOLTS NOMINAL 500.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 9 |
Supersedes
This item replaces cancelled NIINs 011448949 · 011580896. An older drawing citing one of those numbers resolves here.