NSN 6120-01-690-2461 · NIIN 016902461 · FSC 6120
NO DASHES 6120016902461
In Stock
POWER SUPPLY
Transformers: Distribution and Power Station
Technical characteristics
15 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.5 |
| AJJY | DOCUMENT SOURCE | 7AFQ6 |
| CWHQ | INPUT CONNECTION TYPE | SINGLE OPERATING POWER RQMT CONNECTOR, PLUG |
| CWHT | INPUT CONNECTION QUANTITY | 3 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -10.0 TO 45.0 |
| BGQR | OUTPUT WATTAGE RATING | SINGLE POWER OUTPUT WATTS NOMINAL 60.0 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | MIDSPAN |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 100.0 AND AC VOLTS MAXIMUM 240.0 |
| APPA | OUTPUT VOLTAGE RATING | SINGLE POWER OUTPUT DC VOLTS NOMINAL 55.0 |
| CWHM | INPUT CURRENT RATING | SINGLE OPERATING POWER RQMT AC AMPERES NOMINAL 1.5 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 5.94 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 2.44 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 60.0 |
| AMQY | INSTALLATION DESIGN | BENCH |