NSN 5950-01-057-0524 · NIIN 010570524 · FSC 5950
NO DASHES 5950010570524
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.127 AND INCHES MAXIMUM 0.133 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ NOMINAL 25.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 0.625 |
| ADAR | BODY OUTSIDE DIAMETER | INCHES MAXIMUM 1.590 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 1 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 200.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 600.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 900.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 35.40 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 17.70 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 14.60 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 27.90 AND AC VOLTS NOMINAL 28.50 AND AC VOLTS NOMINAL 29.40 AND AC VOLTS NOMINAL 30.00 |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 14 |