NSN 5950-01-331-3161 · NIIN 013313161 · FSC 5950
NO DASHES 5950013313161
In Stock
REACTOR
Coils and Transformers
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 3.100 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.590 AND INCHES MAXIMUM 2.610 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.990 AND INCHES MAXIMUM 2.010 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 2.020 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 2.500 |
| ACYF | INDUCTANCE TYPE | FIXED |
| ACYV | INDUCTANCE RATING | SINGLE COMPONENT SINGLE WINDING MILLIHENRIES NOMINAL 2.25 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ NOMINAL 16.0 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AKDX | WINDING QUANTITY | 1 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BKPL | RATING METHOD | SINGLE COMPONENT SINGLE WINDING ELECTRICAL |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE WINDING AMPERES DC MAXIMUM 7.0 |
| CRGS | DC RESISTANCE RATING IN OHMS | 0.090 |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 13973-841280 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 2 |