NSN 5950-00-061-7006 · NIIN 000617006 · FSC 5950
NO DASHES 5950000617006
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AEHZ | MAXIMUM OPERATING TEMP | FAHRENHEIT 160.0 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 4.000 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 5.375 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 4.750 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.750 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.000 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 6.500 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.228 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES DC MAXIMUM 300.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 4.30 AND AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 865.00 AND AC VOLTS NOMINAL 930.00 AND AC KILOVOLTS NOMINAL 1.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 7 |