NSN 6130-01-166-8444 · NIIN 011668444 · FSC 6130
NO DASHES 6130011668444
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Technical characteristics
13 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 8.050 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 5.100 |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 12000.0 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL -5.2 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL 30.0 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS NOMINAL -30.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS 0.1 TO 50.0 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES MINIMUM 0.10 AND DC AMPERES MAXIMUM 1.00 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES MINIMUM 0.60 AND DC AMPERES MAXIMUM 8.00 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES MINIMUM 10.00 AND DC AMPERES MAXIMUM 60.00 |
| CWGH | OUTPUT CURRENT RATING | FOURTH POWER OUTPUT DC AMPERES MAXIMUM 0.25 |