NSN 5915-00-427-5233 · NIIN 004275233 · FSC 5915
NO DASHES 5915004275233
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
60 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 11.750 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 8 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 75.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 12.500 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 8.250 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FOURTH FUNCTION 4TH RADIO INTERFERENCE 100.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.319 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 0.0 TO 33.0 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 9.000 |
| AFGA | OPERATING TEMP RANGE | CELSIUS 0.0 TO 65.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHCG | MAXIMUM TEMP RISE | CELSIUS 30.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION THREADED STUD OUTPUT 6 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | THIRD FUNCTION THREADED STUD GROUND 1 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 440.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 440.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 440.0 |
| CQRG | BODY MATERIAL | METAL |
| CTJS | UNPACKAGED UNIT WEIGHT | POUNDS NOMINAL 44.000 |
| STYL | STYLE DESIGNATOR | |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 4.4 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 1.15 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 4.4 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIFTH FUNCTION 5TH RADIO INTERFERENCE 100.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| AKNA | INCLOSURE TYPE | ENCASED |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FOURTH FUNCTION 4TH RADIO INTERFERENCE 400.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION THREADED STUD INPUT 6 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SIXTH FUNCTION 6TH RADIO INTERFERENCE 400.0 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 10.500 |
| ADAT | BODY WIDTH | INCHES NOMINAL 10.000 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | THIRD FUNCTION 3RD RADIO INTERFERENCE 75.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 1.15 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 4.4 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 1.15 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 75.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIFTH FUNCTION 5TH RADIO INTERFERENCE 400.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | THIRD FUNCTION 3RD RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 60.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SIXTH FUNCTION 6TH RADIO INTERFERENCE 100.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |