NSN 5915-01-193-5655 · NIIN 011935655 · FSC 5915
NO DASHES 5915011935655
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Application: RECEIVING SET,COUNTERMEASURES AN/WLQ-4(V)
Technical characteristics
41 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 14.130 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.250 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 12.730 |
| ADAT | BODY WIDTH | INCHES NOMINAL 5.000 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.000 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 55.0 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 75.0 |
| AGAV | END ITEM IDENTIFICATION | RECEIVING SET,COUNTERMEASURES AN/WLQ-4(V) |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | THIRD FUNCTION 3RD RADIO INTERFERENCE 60.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 60.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 15.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | THIRD FUNCTION 3RD RADIO INTERFERENCE 15.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 15.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.25 AND VOLTS DC 1ST RADIO INTERFERENCE 6.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 1.25 AND VOLTS DC 3RD RADIO INTERFERENCE 6.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.25 AND VOLTS DC 2ND RADIO INTERFERENCE 6.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHCG | MAXIMUM TEMP RISE | CELSIUS 20.0 |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | FIRST FUNCTION THREADED HOLE(S) 6 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SECOND FUNCTION THREADED STUD(S) 4 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION THREADED STUD INPUT 3 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION THREADED STUD OUTPUT 3 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 125.0 AND VOLTS DC 1ST RADIO INTERFERENCE 600.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 125.0 AND VOLTS DC 3RD RADIO INTERFERENCE 600.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 125.0 AND VOLTS DC 2ND RADIO INTERFERENCE 600.0 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.164 |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | KILOVOLTS AT SEA LEVEL 1.2 |
| CRST | BODY SURFACE TREATMENT | TIN |
| STYL | STYLE DESIGNATOR |