NSN 5915-00-281-0273 · NIIN 002810273 · FSC 5915
NO DASHES 5915002810273
In Stock
FILTER,BAND PASS
Filters and Networks
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 637.50 AND HERTZ BLANK 722.50 AND HERTZ BLANK 807.50 AND HERTZ BLANK 892.50 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION TURRET OUTPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | THIRD FUNCTION TURRET GROUND 1 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 1.8 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION TURRET INPUT 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED STUD(S) 2 |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 600.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 600.0 |
| ADAT | BODY WIDTH | INCHES NOMINAL 3.375 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 3.625 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.500 |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 765.0 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 4.031 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 4.219 |
| STYL | STYLE DESIGNATOR | |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.190 |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 722.50 AND HERTZ BLANK 807.50 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM BLANK 46.0 AND NOMINAL BLANK 1.8 AND MINIMUM BLANK 42.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED INDUCTANCE-CAPACITANCE BLANK |