Home / MS parts / NSN 5915-01-098-0741
NSN 5915-01-098-0741  ·  NIIN 010980741  ·  FSC 5915
NO DASHES 5915010980741
In Stock

FILTER,BAND PASS

Filters and Networks

Technical characteristics

27 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABKWOVERALL HEIGHTINCHES MAXIMUM 3.462
ADAQBODY LENGTHINCHES MAXIMUM 1.303
ADATBODY WIDTHINCHES MAXIMUM 0.775
ADAUBODY HEIGHTINCHES MAXIMUM 3.275
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 0.750
AFGAOPERATING TEMP RANGECELSIUS -46.0 TO 85.0
AFSVAVERAGE LIFE RATING IN HOURS10000.0
AHAJREFERENCE FREQUENCY PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 39.0
AHAUINPUT IMPEDANCE PER FUNCTION W/LOADLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0
AHAVOUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTLOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0
AHBNINPUT TERMINAL MANUFACTURER CODE98278
AHBPINPUT TERMINAL IDENTIFICATION141-1002-0002
AHBSOUTPUT TERMINAL MANUFACTURER CODE98278
AHBTOUTPUT TERMINAL IDENTIFICATION141-1002-0002
AHBZVOLTAGE STANDING WAVE RATIO PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED BLANK 1.5
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED TERMINAL 2
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSLOCATION NOT OTHERWISE SPECIFIED BLANK 0.8
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 1.46 AND MEGAHERTZ BLANK 2.00 AND MEGAHERTZ BLANK 76.00 AND MEGAHERTZ BLANK 111.46
CQRGBODY MATERIALMETAL
CRBBFREQUENCY BAND WIDTH PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 2.00 AND MEGAHERTZ BLANK 76.00
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM BLANK 50.0 AND MAXIMUM BLANK 1.0
CRBNVOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTIONLOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 2.0 AND MEGAHERTZ BLANK 76.0
FEATSPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ3.000
STYLSTYLE DESIGNATOR