Home / MS parts / NSN 5945-00-259-5891
NSN 5945-00-259-5891  ·  NIIN 002595891  ·  FSC 5945
NO DASHES 5945002595891
In Stock

RELAY,ELECTROMAGNETIC

Relays and Solenoids

Technical characteristics

20 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAJDTHREAD CLASS2A
ABHPOVERALL LENGTHINCHES NOMINAL 1.330
ABKWOVERALL HEIGHTINCHES NOMINAL 1.890
ABMKOVERALL WIDTHINCHES NOMINAL 0.960
ADZCENVIRONMENTAL PROTECTIONHERMETIC
AKDXWINDING QUANTITY1
APCNCOIL QUANTITY1
APNAWINDING DC RESISTANCE RATINGSINGLE WINDING OHMS NOMINAL 200.0
APNPDUTY TYPEINTERMITTENT
AXHRMOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY THREADED STUD(S) 3
AYSCPILE-UP MAIN CONTACT FORM ARRANGEMENT1A AND 2C
CMLPTHREAD QUANTITY PER INCH40
CQJXNOMINAL THREAD SIZESINGLE MOUNTING FACILITY INCHES 0.112
CQYJMOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY TRIANGLE
CSQJCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLESINGLE MOUNTING FACILITY INCHES NOMINAL 1.000
CSXFOPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 27.5
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES DC 3.0
CWABMAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSDC 30.0
THSDTHREAD SERIES DESIGNATORSINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYALL FUNCTIONS PIN 10