Home / MS parts / NSN 5925-00-948-6026
NSN 5925-00-948-6026  ·  NIIN 009486026  ·  FSC 5925
NO DASHES 5925009486026
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

33 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ADAQBODY LENGTHINCHES MAXIMUM 1.500
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
AAQLBODY STYLE
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 2.0
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.780
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 300.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.375
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.190 AND MAXIMUM AT 200 PCT 0.600
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND HERMETICALLY SEALED
FREQFREQUENCY IN HERTZ400.0
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 4
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0
ABXDBUSHING LENGTHINCHES NOMINAL 0.375
CMLPTHREAD QUANTITY PER INCH32
ADATBODY WIDTHINCHES MAXIMUM 1.250
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.875
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC
CPRQRESET METHODMANUAL