Home / MS parts / NSN 5925-00-369-7747
NSN 5925-00-369-7747  ·  NIIN 003697747  ·  FSC 5925
NO DASHES 5925003697747
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

38 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 120.0 AND DC 50.0
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39019
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED
CPRWACTUATOR FUNCTIONTRIP-RESET
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39019 TO 2
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ABXDBUSHING LENGTHINCHES MINIMUM 0.360 AND INCHES MAXIMUM 0.380
ADAQBODY LENGTHINCHES MAXIMUM 1.562
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.500 AND MAXIMUM AT 200 PCT 9.000
AFJNFRAGILITY FACTORMODERATELY RUGGED
CRTKSWITCH TERMINAL TYPEPIN
AKPXPOLE QUANTITY1
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 2
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 500.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 8.0
CQJXNOMINAL THREAD SIZEINCHES 0.375
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 0.5 AND DC 0.5
AAQLBODY STYLE
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 50.0
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.700
ADATBODY WIDTHINCHES MAXIMUM 0.625
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MAXIMUM 0.906