Technical characteristics from the federal item record
MRCRequirementValue
AAQLBODY STYLE
ABHPOVERALL LENGTHINCHES NOMINAL 4.260
ABKWOVERALL HEIGHTINCHES MAXIMUM 3.250
ABMKOVERALL WIDTHINCHES NOMINAL 3.690
AEBVUNTHREADED MOUNTING HOLE DIAMETERINCHES MINIMUM 0.167 AND INCHES MAXIMUM 0.177
AFJNFRAGILITY FACTORMODERATELY RUGGED
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 4
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 40.0 AND AMPERES DC 40.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 200.0 AND DC 200.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 25000.0 AND DC 25000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 16.000 AND MAXIMUM AT 200 PCT 80.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT AND FUNGUS RESISTANT AND HERMETICALLY SEALED
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 25.0
FREQFREQUENCY IN HERTZ400.0
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-83383
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 6
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 81349--83383 TO 04-08