Home / MS parts / Electrical & Electronic Components / NSN 5962-01-290-1277
NSN 5962-01-290-1277  ·  NIIN 012901277  ·  FSC 5962
NO DASHES 5962012901277
In Stock

MICROCIRCUIT,DIGITAL

Microcircuits, Electronic

Technical characteristics

19 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ADAQBODY LENGTHINCHES MAXIMUM 0.390
ADATBODY WIDTHINCHES MINIMUM 0.235 AND INCHES MAXIMUM 0.260
ADAUBODY HEIGHTINCHES MINIMUM 0.045 AND INCHES MAXIMUM 0.085
AEHXMAXIMUM POWER DISSIPATION RATINGMILLIWATTS 240.0
AFGAOPERATING TEMP RANGECELSIUS -55.0 TO 125.0
AFJQSTORAGE TEMP RANGECELSIUS -65.0 TO 150.0
CBBLFEATURES PROVIDEDMONOLITHIC AND POSITIVE OUTPUTS
CQSJINCLOSURE MATERIALCERAMIC
CQSZINCLOSURE CONFIGURATIONFLAT PACK
CQWXOUTPUT LOGIC FORMTRANSISTOR-TRANSISTOR LOGIC
CQZPINPUT CIRCUIT PATTERNHEX 1 INPUT
CSSLDESIGN FUNCTION AND QUANTITYGATE, INVERTING 6
CTFTCASE OUTLINE SOURCE AND DESIGNATORMIL-M-38510 F-2
CWSGTERMINAL SURFACE TREATMENTSOLDER
CZENVOLTAGE RATING AND TYPE PER CHARACTERISTICVOLTS MAXIMUM POWER SOURCE 7.0
CZEQTIME RATING PER CHACTERISTICNANOSECONDS MAXIMUM PROPAGATION DELAY TIME, LOW TO HIGH LEVEL OUTPUT 27.00 AND NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, HIGH TO LOW LEVEL OUTPUT 24.00
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL---38510
TTQYTERMINAL TYPE AND QUANTITYFLAT LEADS 14
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL---38510 TO 1

Supersedes

This item replaces cancelled NIINs 003403118 · 004287122 · 004919889 · 010127539 · 010144742 · 010210146 · 010696186 · 012562470. An older drawing citing one of those numbers resolves here.